Eric, I believe that I saw a picture of one of your radiation heat jobs. I have installed 6 Baxi boilers here in the Bay Area and have had nothing but problems. What boiler are you using? Need to be in the 92 to 95 % efficiency range pvc pipe vent only.
Til alle jer der bor hjemme i DK. Hvad erfaring har i med de forskellige boilers der er paa det danske market?

Ps. Baxi er lavet i Italy.

Bo
Har et Passat C2 som har kørt upåklageligt i 10 år.
Panthera

[Image: Img_2757-1.jpg]
Sic bisquitus disintegratum
Bruger PH-Stoker 13-300 på 11 år nu.

Kun skiftet en PT-100 føler og en Lambda sonde

--
mvh M@X 2.0
Boltlift - or bust...
[Image: patch7.gif]
Time weighed heavily on the craftsmans shoulders whispering
Compromise!

No true craftsman ever listened!
Fik opsat Passat C1 Januar 2010.

Det første halve år var ikke nemt.
Havde besøg af smeden 3 gange, samt tekniker fra Passat 3 gange.
Der var tilbagebrand flere gange (lugter dejligt i huset længe).
Lambda sonden blev skiftet 3 gange. Hver gang gik der 2-3 uger, så var den gal igen - dårlig ilttilførsel, masser af røg og tilbagebrand. Forklaringen var, at Bosch havde fået lavet et parti dårlige lambda sonder. Til sidst (Juli 2010), da Passat ikke kunne se anden udvej, prøvede de med at skifte styringen. Dette løste problemet og fyret har kørt perfekt siden August 2010.
Efterfølgende fik jeg at vide fra en svend, at der også havde været problemer med deres styringer. Mesteren havde mange gange fortalt mig, at de havde opsat mange hundrede af samme model og at der aldrig havde været problemer[B)]

Et minus er, at smeden ikke længere selv må skifte dele på Passatfyr. De må komme og finde den mulige fejl, for derefter at tilkalde en tekniker fra Jylland, der skal skifte reservedelen.

Mvh.

mp

De dumme er så sikre i deres sag, og de kloge så fulde af tvivl
Hvis I nu lige læser hvad jeg skriver, så er det noget jeg har hørt - period
CA...

For many years I installed Weil-Mclain boilers made in Michigan city ,Indania...both in fuel oil and gas models. Weil-Mclain was bought out some years back by at that time United Tech. Inc and Weil-Mclain started using United Tech elc. controls which had in my estimation too high a failure rate compared to Honeywell elect. controls that they used to have come as standard equipment with their boilers for many years.

I then went to Slant/Fin boilers made in Greenvale,NY... most of my installs are Slant/Fin... Victory series..VSPH cast iron ,sealed combustion,direct vent gas boiler....both in nat.gas and LP gas.The efficency rating is only 86% but they,re a very reliable boiler and have over 100 units out at last count.
In the hi eff. boilers that meet US govt tax credit standards ...we,ve install several Slant/Fin ...BOBCAT series boiler that are a high performance condensing boiler at 93% AFUE.
For the several..3...that we have installed...once they,re set up and adjusted with manometer guages ,they have been trouble free.
These boilers are PVC vented boilers I will add...you can google SLANT/FIN BOILERS and look at the BOBCAT series..[^]

PS...over the years I have bought a few European wood burning boilers and quality has been very good......but through experience I stay away from them because heating distributers will sell them for a few years then for one reason or another...they drop that brand and..or model. Then I can,t get parts or they,re outrageously priced when I do find parts because of shipping from Europe.[xx(]

good luck... with your problems.[Smile]...Eric